NextWindow 2150 - Connection Options
Standard Connections
The standard 2150 connections include a USB Series A plug and a Neltron 4-way
connector, both on flying leads that can be routed and positioned as required by
the OEM. Also included is a small PCB that connects to the Neltron 4-way
and provides a hardware calibration button.
Note: Serial communications are not provided in the standard 2150 product.
|
Pin-outs for USB Series A receptacle, as specified in section 6.5 of the USB specification, version 1.1
|
 |
 |
 |
 |
 |
Neltron 4-way connector |
|
Pin-outs for Neltron 4-way connector
|
Serial Communications Option
The serial option replaces the small PCB with a larger one that contains an
RS232 DB9 serial port, a 12 VDC power input socket and a hardware
calibration button. The PCB is connected to the touch screen via the standard
USB cable (for power) and the Neltron 4-way connector (for serial communications
and calibration).
Note: The serial communications option requires a 12 VDC power supply unit and other components that are
supplied by NextWindow at extra cost. Contact ,
for further information.
|
|

|
Serial: RS232 DB9 socket |
|
12 VDC positive centre power connector |
Custom connection options
Contact
,